Manufacturer: CHAUVIN ARNOUX Kind of display used: LCD Power supply: rechargeable battery Ni-MH AA x6 IP rating: IP54 Interface: Bluetooth Conform to the norm: EN 61010;IEC 61010-1;IEC 61010-2-030;IEC 61326-1;CAT III 600V;EN 61010-2-034 Illumination: yes Measurement memory: 2970 Dimensions: 223x126x70mm Standard equipment: 3 crocodile clips;USB cable;test probe x1;battery charger/power supply;neckstrap;carrying case;manual (CD);test lead;test leads ( 3pcs.);continuity rod;kit for earth ground resistance measurement 15m Measuring instrument features: Pass/Fail function;automatic generation of PDF file with recorded data;magnetized casing Type of meter: appliance meter Continuity test: <10Ω RCD test: general purpose;30mA, 100mA, 300mA, 500mA, 650mA;AC, A-type RCDs #Promotion: utrzymanie_ruchu_20200714;maintenance_202308 Bargraph: yes Measurement: AC voltage;insulation resistance;frequency;resistance;RCD tripping time;earthing resistance;phase sequence;continuity;AC current (with current clamps) Resistance measuring range: 100kΩ;1...10Ω Loop impedance measuring range: 100mΩ...1Ω;400Ω AC voltage measuring range: 2...550V Frequency measuring range: 30...1000Hz Earthing resistance measuring range: 2kΩ;500mΩ...100Ω;1kΩ Battery/ rechargeable battery: rechargeable battery Ni-MH AA x6 Software: dedicated mobile app Insulation resistance measuring ranges: 0...100MΩ;1GΩ Frequency measuring accuracy: ±(0.1%+1 digit) AC voltage measuring accuracy: ±(1% + 2 digit) |