| Item number: CIEN4-5291480 Manufacturer no.: 19800003 EAN/GTIN: n/a |
| |
|
| | |
| TS19 features DataSafe™, Tone or Pulse operation, Talk/Monitor capabilities and last number redial.
- High impedance DataSafeTM operation in monitor mode - Tone (DTMF) and pulse operation - Last number redial - Polarity indication in talk mode
The Fluke Networks TS19 Test Set combines all the essential test set features at an affordable price. This test set was specifically designed for in-house telecom technicians. Its high impedance monitor prevents accidental disruption of service from clipping onto a data line while in monitor mode, thus ensuring the integrity of critical data lines. Features such as tone (DTMF) or pulse operation, talk/monitor capabilities, polarity test button and last number redial make this test set the perfect combination of features and price.
Electrical Specifications
Loop Limit: 2.4 kΩmaximum at 48 VDC (nominal 15 mA minimum loopcurrent) DC Resistance (Talk Mode): 150 Ωtypical at 80 mA current AC Impedance (Monitor Mode): - Low impedance (Ring position) 600 Ωat 1 KHz typical - High impedance (HI Z position) 100 kΩminimum at 1 KHz Rotary Dial Output: 10 pps .5 pps Pulsing Rate: 60 % ± 2 % Percent Break: 800 ms typical Interdigit Interval Leakage During Break: > 50 kΩ DTMF Output: ±1 % maximum Tone Frequency Error Level per Tone Pair: dBm maximum, - dBm minimum High versus Low Tone Difference: 4 dB maximum More information: Technical details | Product colour | Yellow | Weight & dimensions | Weight | 307 g | | Dimensions (WxDxH) | 60.3 x 222 x 85.7 mm | Operational conditions | Operating relative humidity (H-H) | 10 - 80 % |
|
| | |
| | | |
| | | |
| |