Salicru's SLC TWIN PRO2 series UPS systems feature on-line double conversion technology, currently the most advanced for the protection of critical systems as it provides a fully stabilised and filtered sinusoidal supply voltage. The systems come in a tower format and are available in power ratings of 4, 5, 6, 8, 10, 15 and 20 kVA. The Salicru SLC TWIN PRO2's output voltage is always single-phase, featuring a single-phase input of 4 to 20 kVA and a three-phase input of 8 to 20 kVA. All devices with single-phase input provide a unitary output power factor (1), the most optimum for systems and environments with high energy needs. Adaptability is another important feature thanks to the numerous operating modes available: On-line, Batteries, Eco-mode, Bypass, Frequency converter and Parallel redundant. The possibilities of control and monitoring are varied: on the one hand, an LCD display + keypad for local operation of the device, and, on the other, various communication options (USB HID and RS-232 interfaces, and slot for SNMP, RS-485 and AS-400 cards) that enable the UPS to be integrated into standard or virtualised platforms for management, incident notification and remote maintenance. (1) Except 15 and 20 kVA I / I models More information: Weight & dimensions | Width | 250 mm | | Depth | 592 mm | | Height | 576 mm | | Weight | 84000 g | Battery | Battery technology | Lead-Calcium (Pb-Ca) | | Battery recharge time(90%) | 9 h | | Automatic battery test | Yes | | Cold start | Yes | Operational conditions | Operating temperature (T-T) | 0 - 40 °C | | Operating relative humidity (H-H) | 0 - 95 % | | Operating altitude | 0 - 5000 m | Logistics data | Harmonized System (HS) code | 85078000 | Design | Form factor | Tower | | Product colour | Black | | Cooling type | Active | | Built-in fan | Yes | | Display type | LCD | | LED indicators | Yes | | Safety | EN 62040-1; EN 60950-1 | Features | UPS topology | Double-conversion (Online) | | Output power capacity | 8 kVA | | Output power | 7200 W | | Input operation voltage (min) | 190 V | | Input operation voltage (max) | 478 V | | Input frequency | 50/60 Hz | | Output operation voltage (min) | 208 V | | Output operation voltage (max) | 240 V | | Output frequency regulation | 4 Hz | | Output voltage regulation | 1 % | | Number of input phases | 3 | | Number of output phases | 1 | | Efficiency | 90 % | | Input power factor | 0.99 | | Output power factor | 0.9 | | Crest factor | 3:1 | | ECO mode | Yes | | Emergency Power Off (EPO) | Yes | | Overload capacity (10 minutes) | 110 % | | Overload capacity (1 minute) | 130 % | | Output voltage Total Harmonic Distortion (THD) | 5 % | | Input current Total Harmonic Distortion (THD) | 5 % | | Total Harmonic Distortion (THD) (linear load) | 2 % | | Total Harmonic Distortion (THD) (non-linear load) | 5 % | | Noise level | 60 dB | | Surge protection | Yes | | Power protection features | Under voltage | | Maximum number of paralleling UPSs | 3 | | Synchronisation with mains | 4 Hz | | Synchronisation without mains | 0.05 Hz | | Temperature voltage compensation | Yes | | Maintenance-free | Yes | Ports & interfaces | AC outlet types | C13 coupler | | AC outlets quantity | 2 AC outlet(s) | | Number of output IEC jumpers | 2 | | USB port | Yes | | USB 2.0 ports quantity | 1 | | Serial interface | Yes | | Serial interface type | RS-232 | | RS-232 ports | 1 | | Parallel ports quantity | 3 | | Emergency Power Off (EPO) connector | Yes | Other features | Battery type | AGM | | Bypass | Hybrid, Nill | | I/O ports | Intelligent slot |
|