Riello SDH 2200 A3 uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA 1980 W 8 AC outlet(s)
Riello SDH 2200 A3 uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA 1980 W 8 AC outlet(s)
Riello SDH 2200 A3 uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA 1980 W 8 AC outlet(s)
Riello SDH 2200 A3 uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA 1980 W 8 AC outlet(s)
Riello SDH 2200 A3 uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA 1980 W 8 AC outlet(s)
Riello SDH 2200 A3 uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA 1980 W 8 AC outlet(s)
Riello SDH 2200 A3 uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA 1980 W 8 AC outlet(s)
Riello SDH 2200 A3 uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA 1980 W 8 AC outlet(s)
Riello SDH 2200 A3 uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA 1980 W 8 AC outlet(s)
Item number:
     CIEN8-69223736
Manufacturer:
     Riello UPS
Manufacturer no.:
     CSDH2K2AA3
EAN/GTIN:
     n/a
Search terms:
HF relays
HF relay
High-frequency relay
High-frequency relays
SENTINEL DUAL is the high density version of the Sentinel Pro range of double-conversion on-line UPS.

SENTINEL DUAL is designed to power critical loads such as servers, storage systems, telephone equipment, medical systems and industrial applications.

The UPS is ideal for Blade servers with an input power factor close to Unity (1). The UPS has can be used as tower UPS or within a rackmount cabinet, and takes up only 2U in height.

SENTINEL DUAL has a modern design, choice of functional formats, and represents the state-of-the-art technology from the Riello UPS research & development team. The UPS can achieve an on-line operating efficiency of 92%.

For critical business continuity applications requiring long runtimes, SENTINEL DUAL can be installed with battery extension packs (ER models) with their own internal battery chargers to maintain sensible recharge times.

The UPS also incorporates the Riello UPS ‘power-off’ function found in other ECO Line UPS. Sentinel Dual is designed to save energy when no loads are connected.

SIMPLIFIED INSTALLATION
- Tower or Rackmount UPS: SENTINEL DUAL can be installed as tower or 19” rackmount UPS, with a front mimic panel that can be turned through 90º to suit the installation.
- Noise Free Operation (<40dBA): the UPS can be installed in any environment thanks to its PWM digitally-controlled high frequency inverter.
- High Temperature Operation: UPS components are sized for high temperature operation up to 40ºC and are not therefore stressed during normal operational environments.
- EnergyShare: Sentinel Dual output sockets can be programmed to disconnect less critical loads when the mains power fails.

REDUCED MANAGEMENT COSTS
SENTINEL DUAL can be programmed remotely via software or set manually from the front mimic panel to operate in a range of energy saving operating modes:
- On Line: maximum power protection and output voltage waveform quality
- ECO: to increase operating efficiency to 98% and provide line interactive protection
- Smart Active: with the UPS selecting automatically its operating mode - ECO or On-Line dependent upon the reliability and quality of the local mains power supply.
- Backup: for emergencies only with the UPS only operating when mains power fails
- Frequency converter: from 50 to 60Hz or 60 to 50Hz.

ADVANCED COMMUNICATION
SENTINEL DUAL offers maximum flexibility for integrations with any communication system.
- Multiplatform communication for all operating systems and network environments, Powershield3 supervision and shut-down software included for Windows 7, 2008, Vista, 2003, XP, Linux, Mac OS X, Sun Solaris and VMware ESX operating systems and other Unix operating systems.
- UPS Tools configuration and personalisation software supplied as standard.
- RS232 serial port and opto-isolated contacts.
- USB port
- Slot for communication cards such as Modbus/Jbus, TCP/IP, SNMP and relay contacts.

HIGH OUTPUT VOLTAGE QUALITY
- Even with distorting loads (IT loads with a crest factor of up to 3:1).
- High short circuit current on bypass.
- High overload capacity: 150% from inverter (even with no mains power).
- Filtered, stabilised, reliable (On Line double conversion technology (VFI in accordance with EN62040-2 class C2) standard with filters to suppress atmospheric disturbances.
- Load power factor correction: incoming UPS power factor close to 1 and sinusoidal current absorption.

HIGH LEVELS OF BATTERY RELIABILITY
- Automatic and manual battery tests
- Batteries are ‘hot-swappable’ and user replaceable.
- Unlimited battery runtime extension using battery extension packs.

OTHER FEATURES
- Output voltage can be selected using software (220-230-240V).
- Auto-restart when mains power returns (programmed via software)
- Stand-by on Bypass: when the machine is switched off, it automatically goes into bypass operation with batteries charging.
- Power-Off with zero load connected to save energy
- Low battery warning
- Power-on delay
- Full microprocessor control.
- Automatic bypass without interruption
- Status, measurements and alarms available on the front panel mimic panel and LCD
- UPS firmware upgrade via PC platform
- Input protection including a user reset thermal switch (up to 1500VA)
- Back-feed protection
- Manual option to switch to bypass.
More information:
Weight & dimensions
Width
87 mm
Depth
625 mm
Height
450 mm
Weight
30500 g
Battery
Battery technology
Sealed Lead Acid (VRLA)
Battery recharge time
4 h
Operational conditions
Operating temperature (T-T)
0 - 40 °C
Operating relative humidity (H-H)
5 - 95 %
Design
Form factor
Tower
Product colour
Black
Housing material
Plastic, Steel
Rack capacity
2U
Safety
EN 62040-1:2008; EN 62040-1/EC:2009; EN 62040-1/A1:2013 and Directive 2014/35/EU
Certification
CE
Features
UPS topology
Double-conversion (Online)
Output power capacity
2.2 kVA
Output power
1980 W
Waveform
Sine
Input operation voltage (min)
140 V
Input operation voltage (max)
276 V
Input frequency
50/60 Hz
Surge energy rating
300 J
Number of input phases
1
Number of output phases
1
Efficiency
98 %
Power factor
0.99
Crest factor
3:1
Overload capacity (1 minute)
110 %
Noise level
40 dB
Surge protection
Yes
Packaging data
Manual
Yes
Ports & interfaces
AC outlet types
C12 coupler, C14 coupler
Power plug
C13 coupler
AC outlets quantity
8 AC outlet(s)
USB 2.0 ports quantity
1
Serial interface
Yes
Serial interface type
RS-232
Serial ports quantity
1
RS-232 ports
1
Other search terms: High frequency relays, High frequency relay, Delay relay, Mains monitoring relays, Mains monitoring relay, Voltage relay, Voltage relays, Voltage monitoring relay, Voltage monitoring relays, UPS, USV, UPS system, Uninterruptible power supply, UPS rack mounting kit, riello ups, hf relays, UPSs, uninterruptible power supply, uninterruptible power supplies, uninterruptible power source, uninterruptible power sources
An overview of the best conditions of all 2 offers1
Delivery period
Stock level
Price
from £ 828.79*
Select conditions yourself
Share itemAdd item to shopping list
* Prices with asterisk are net prices excl. statutory VAT.
Our offer is only aimed at companies, public institutions and freelancers.