| ![](/p.gif) |
![](/p.gif) |
| Item number: CIEN9-68254163 Manufacturer no.: GXT5-10KIRT5UXLE EAN/GTIN: 767041026764 |
| |
|
| ![](/p.gif) | ![](/p.gif) |
![](/p.gif) | The Liebert GXT5 UPS in an on-line double conversion USP solution which offers premium power outage protection and continuous power conditioning in a compact and flexible deployment system. This single phase UPS operates with a high power efficiency and it is ideally suited to protect critical infrastructure in both centralized and edge of network applications. More information: Weight & dimensions | Width | 430 mm | ![](/p.gif) | Depth | 630 mm | ![](/p.gif) | Height | 217 mm | ![](/p.gif) | Weight | 74500 g | ![](/p.gif) | Package width | 646 mm | ![](/p.gif) | Package depth | 816 mm | ![](/p.gif) | Package height | 520 mm | ![](/p.gif) | Package weight | 93000 g | Battery | Battery technology | Sealed Lead Acid (VRLA) | ![](/p.gif) | Battery capacity | 9 Ah | ![](/p.gif) | Battery voltage | 12 V | ![](/p.gif) | Number of batteries supported | 16 | ![](/p.gif) | Typical backup time at full load | 2 min | ![](/p.gif) | Typical backup time at half load | 7 min | ![](/p.gif) | Battery recharge time(90%) | 5 h | ![](/p.gif) | Hot-swap battery | Yes | Technical details | Sustainability certificates | RoHS | ![](/p.gif) | Compliance certificates | RoHS | Operational conditions | Operating temperature (T-T) | 0 - 40 °C | ![](/p.gif) | Storage temperature (T-T) | -15 - 40 °C | ![](/p.gif) | Operating relative humidity (H-H) | 0 - 95 % | ![](/p.gif) | Storage relative humidity (H-H) | 0 - 95 % | ![](/p.gif) | Operating altitude | 0 - 3000 m | Logistics data | Harmonized System (HS) code | 85078000 | Design | Form factor | Rackmount/Tower | ![](/p.gif) | Product colour | Black | ![](/p.gif) | Rack capacity | 5U | ![](/p.gif) | Cooling type | Active | ![](/p.gif) | Display type | LCD | ![](/p.gif) | International Protection (IP) code | IP20 | ![](/p.gif) | Safety | IEC62040-1:2008 | ![](/p.gif) | Certification | CE, EMI/EMC/C-Tick EMC, ESD | Features | UPS topology | Double-conversion (Online) | ![](/p.gif) | Output power capacity | 10 kVA | ![](/p.gif) | Output power | 10000 W | ![](/p.gif) | Waveform | Pure sine | ![](/p.gif) | Input operation voltage (min) | 176 V | ![](/p.gif) | Input operation voltage (max) | 288 V | ![](/p.gif) | Input frequency | 50/60 Hz | ![](/p.gif) | Output operation voltage (min) | 230 V | ![](/p.gif) | Output operation voltage (max) | 240 V | ![](/p.gif) | Output frequency | 50/60 Hz | ![](/p.gif) | Output voltage regulation | 3 % | ![](/p.gif) | Number of input phases | 1 | ![](/p.gif) | Number of output phases | 1 | ![](/p.gif) | Single-phase input voltage supported | 200,208,220,230,240 V | ![](/p.gif) | Efficiency | 95 % | ![](/p.gif) | Efficiency (On-line mode) | 95 % | ![](/p.gif) | Power factor | 1 | ![](/p.gif) | Input power factor | 0.99 | ![](/p.gif) | Output power factor | 1 | ![](/p.gif) | Emergency Power Off (EPO) | Yes | ![](/p.gif) | Overload capacity (5 minute) | 125 % | ![](/p.gif) | Overload capacity (1 minute) | 150 % | ![](/p.gif) | Noise level | 55 dB | ![](/p.gif) | Power protection features | Overload | ![](/p.gif) | Audible alarm(s) | Yes | Ports & interfaces | AC outlet types | C13 coupler, C19 coupler, IEC 320, Terminal | ![](/p.gif) | Power plug | Terminal | ![](/p.gif) | AC outlets quantity | 8 AC outlet(s) | ![](/p.gif) | USB port | Yes | ![](/p.gif) | Serial ports quantity | 1 | ![](/p.gif) | RS-232 ports | 1 | Other features | Battery type | VRLA | ![](/p.gif) | Output voltage | 230 V |
|
| ![](/p.gif) | ![](/p.gif) |
![](/p.gif) | | ![](/p.gif) | ![](/p.gif) |
![](/p.gif) | Other search terms: ups system, UPSs, uninterruptible power supply, uninterruptible power supplies, uninterruptible power source, uninterruptible power sources |
| ![](/p.gif) | ![](/p.gif) |
| |